Почему-то я его (текст стандарта) никак не найду, и приходится пользоваться всякими перепевами.
Возьмем, к примеру, AN-1057 от National
"Although the potential difference between the data-pair conductors determines the signal without officially involving ground (/**НА ЭТОМ "Although" ВСЕ У НАС И ДЕРЖИТСЯ****/), the bus needs (/**ТЕМ НЕ МЕНЕЕ - "need"! ***/) a ground wire to provide a return path for induced common-mode noise and currents, such as the receivers’ input current. A typical mistake is to connect two nodes with only two wires (/*****!!!!!!!!!!! О ЧЕМ СОБСТВЕННО И РАЗГОВОР!!!!!*******/). If you do this, the system may radiate high levels of EMI, because the common-mode return current finds its way back to the source, regardless of where the loop takes it. An intentional ground provides a low-impedance path in a known location, thus reducing emissions."
Т.е. работать-то оно будет, но будет и излучать, и принимать помехи соответственно, и о защите входов/выходов надо бы особенно озаботиться, о чем собственно и был вопрос.
Аналогичные мысли можно найти и в других AN.
Кроме того, нигде не сказано, что второй выход передатчика ОБЯЗАН пропустить через себя возвращающийся через сопротивление нагрузки ток от первого выхода. Очевидно, есть формирователи, которые без общей земли вообще работать не будут.
Так что - обоснуйте, где там "по определению".
И я не буду задавать глупых (?) вопросов.
Заранее благодарен!