30. 05000280 - SPI Master boot mode does not work well with Atmel Data flash devices:
DESCRIPTION:
The boot ROM code causes booting from Atmel serial dataflash devices to fail if the boot stream is larger than the SPI device's page size.
This only happens if the dataflashes are operating in Standard Addressing Mode.
WORKAROUND:
Use the series D devices (i.e., AT45DB642D) in the Power-Of-2 Addressing Mode.
APPLIES TO REVISION(S):